✓FCITS Certified Flooring Inspector · South Florida
Preventing flooring
failures before
they cost you
thousands.
Commercial installation, ASTM moisture testing and forensic inspections from a team that has spent 25+ years learning why floors fail, and building them so they don’t.
Most flooring failures begin in layers nobody sees. Scroll to build the floor the way we do, from the slab up.
Section A–A · Floor assemblyStep 1 / 4
Finish floorLVT · 5 mm
Self-leveling underlayment6 mm
Concrete slabSubstrate
RH 78%
AssessTestPrepareInstall
01 · ASSESS
Read the site before anything goes down.
We review project conditions, the specified flooring system and the manufacturer’s requirements, so problems are caught on paper instead of on the floor.
Site conditionsSpecs reviewMaterial selection
02 · TEST
Measure the moisture in the slab.
Probes go into the concrete to measure relative humidity at depth. If the reading is over the manufacturer’s limit, we know before the adhesive does.
ASTM F2170ASTM F1869ASTM F2659
03 · PREPARE
Build a substrate the floor can trust.
Primer, self-leveling and moisture mitigation review, matched to the system going on top. Flat, sound and dry.
Self-levelingPrimerMitigation review
04 · INSTALL
Install with an inspector’s eye.
The finish floor goes down with the attention to detail of someone who investigates failures for a living, and around your schedule when needed.
After-hoursHealthcare-readyDocumented
Moisture testing
Know the number before you glue.
The right test depends on the substrate, the project specifications and the flooring manufacturer’s requirements. We run the method your warranty asks for.
Good to know
Preliminary meter readings flag areas for further investigation, but they do not replace the quantitative testing your flooring manufacturer specifies.
Inspections & consulting
When a floor fails, find out why.
We examine site conditions, materials, preparation and installation, weigh them against manufacturer instructions and project specs, and tell you clearly what caused the problem and what to do next.
Lifting & peaking
Boards or tiles rising off the substrate.
Gaps & separation
Seams opening as the floor shrinks or moves.
Loose flooring
Hollow sounds, debonding and failed adhesive.
Moisture problems
Cupping, staining, odors and adhesive breakdown.
Forensic Inspection Report
SAMPLE · WOOD FLOORING · BOCA RATON
FCITS CERTIFIED
Observed
Cupping across 60% of the living area, worst near the patio door.
Tested
Slab RH above the manufacturer’s limit at 3 of 4 probe sites.
Cause
Moisture from the substrate, not a product defect.
Next steps
Remove, mitigate, retest to ASTM F2170, reinstall.
RK
Waseem “Ricky” Khawaja
FCITS Certified Flooring Inspector · 25+ years
Sectors
Floors for spaces that work hard.
From hospital corridors to country club dining rooms, each sector brings its own traffic, hygiene and scheduling demands.
HEALTHCARE
Hospitals & Medical
Seamless, cleanable floors installed around patient care.
WORKPLACE
Corporate Offices
Patterned carpet tile and LVT, often installed after hours.
HOSPITALITY
Hotels
Durable decorative floors for lobbies, rooms and corridors.
FOOD & BEVERAGE
Restaurants
Floors that stand up to spills, carts and long shifts.
SENIOR LIVING
Assisted Living
Safe, comfortable surfaces for residents and staff.
ACTIVE
Fitness Centers
Resilient flooring built for heavy equipment and impact.
LEISURE
Country Clubs
Wood-look and decorative flooring with a premium finish.
RETAIL
Retail Boutiques
Distinctive floors that sell the brand from the door.
25+
Years of hands-on experience
28
Google reviews
3
ASTM moisture methods
8
Commercial sectors served
Reviews
Clients come back for the honesty.
Homeowners, builders and property managers rate us on Google for straight answers and fair pricing.